TABLE VIII. Classification of defects - Continued.
Category |
Defect |
Method of examination |
Minor 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 |
AQL 150 Defects/100 units Stowage, improper assembly or installation (see 3.4.2). Weldment, improper assembly or installation (see 3.4.5). Vehicle components, improper assembly or installation (see 3.5.2). Sealing, improper assembly or installation (see 3.5.9). Bearings, improper assembly or installation (see 3.5.9.2). Hatches, improper assembly, installation, dessicant (see 3.6.15). Ramp system, improper assembly or installation (see 3.5.15). Bilge pump, improper assembly or installation (see 3.5.16). Trim vane, improper assembly or installation (see 3.5.17). Vision devices, improper assembly, installation dessicant (see 3.5.l9). Targeting station, improper fits, adjustments, installation, welds, seals pressure switch (see 3.5.20). AZ and EL drive system, improper assembly or installation (see 3.5.20.2.2). TSCD, improper assembly or installation (see 3.5.21). Electrical system, improper assembly or installation (see 3.5.25). Hydraulic control system, improper assembly, installation, fluid level, pressure (see 3.5.27). Controls, improper assembly or installation (see 3.5.28) Safety interlocks, improper assembly or installation (see 3.5.29). Markings and data plates, improper location, size, missing, defective (see 3.6.3 thru 3.6.4). Workmanship, improper installation, fit, adjustment, welds, scale adhesion, hardware or sheet metal (see 3.7). |
Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and functional Visual and SIE 3/ Visual and functional Visual Visual and functional |
1/ Any fuel leakage constitutes a special defect and shall result in total inspection of the lot for this
defect.
2/ Filament failures are not to be classified as major or minor defects.
3/ SIE = Standard Inspection Equipment.
31
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business