MIL-DTL-45360H(AT)
3.2.4 Personnel heater and fuel pump. The personnel heater and fuel pump shall be in
ready-to-use condition. The heater exhaust openings shall be closed with a plastic plug
conforming to MIL-C-5501/7 (see figure 6), or closed with tape conforming to type IV of
MIL-T-22085. A warning tag, bearing the information "HEATER EXHAUST OPENINGS
CLOSED, REMOVE PLUG OR TAPE BEFORE OPERATING", shall be attached to the heater
controls.
3.2.5 Fuel. Unless otherwise specified (see 6.2), the vehicle will be shipped with 1/4 tank
of JP-8 fuel.
3.2.6 Backrests and seats. Cushions of backrests and seats shall not be covered. If
cushions are received packaged, they shall be stowed as received in the crew compartment.
3.2.7 Vehicle closure. Vehicle closure kits shall not be provided for Level B shipment
and storage.
3.2.8 Tow hooks. Tow hooks shall be removed for overseas shipment only
(see 3.1.9.10).
3.2.9 Engine compartment access panels. Engine compartment access panels in the crew
compartment shall not be removed.
3.2.10 Bilge pump outlets. Bilge pump outlets shall be closed with plastic plugs
conforming to MIL-C-5501/7 (see figure 6), or closed with tape conforming to type IV of
MIL-T-22085. A warning tag, bearing the information "BILGE PUMP OUTLETS CLOSED
PRIOR TO OPERATING BILGE PUMP, REMOVE PLUGS OR TAPE FROM OUTLETS",
shall be secured to the bilge pump operating switch.
3.2.11 Machine gun pintle mount. For CONUS shipment only, machine gun pintle mount
shall not be removed.
3.2.12 Stowage and securement of BII (M1059, M1059A3, M58). BII and items
removed for shipment may be stowed on top side of vehicle and secured as required.
3.3 Materials. Materials shall be as specified herein and in referenced specifications and
drawings. Material shall be free from all defects and imperfections that might affect the
serviceability and appearance of the finished product (see 4.5.1).
3.3.1 Recycled, virgin and reclaimed materials. There are no requirements for the
exclusive use of virgin materials. The use of recycled or reclaimed (recovered) materials is
acceptable provided that all other requirements of this specification are met (see 4.5.1 and 6.5.1).
18