MIL-PRF-62195D(AT)
3.3.2.4 Smoke generating kit. The two elements of this kit, the hull segment and the
engine segment, shall be capable of generating smoke in volume through the vehicle's engine
exhaust outlets on demand. Both the right and left exhaust outlets shall emit white smoke.
3.3.3 Power package. The power package shall consist of an engine conforming to
MIL-PRF-62177 and a transmission conforming to the contractor's specifications.
3.3.4 Mechanical transmission power takeoff (PTO). The PTO shall drive a mechanical
type transmission of the reduction gear, clutch type.
3.3.5 Fuel system. When ascending and descending longitudinal grades and side slopes,
in forward and reverse, the fuel system shall maintain fuel supply to the engine. The entire fuel
system shall exhibit no leakage.
3.3.5.1 Fuel tanks. Fuel tanks shall allow a fuel filling rate of 50 gallons per minute
(gal/min). The fuel tanks shall be clean of rust, moisture, scale, welding spatter, and slag
3.3.5.2 Fuel lines. Fuel lines shall not leak fuel and provisions shall be made to assure the
internal cleanliness of fuel lines and connections.
3.3.5.3 Emergency fuel shut-off. Emergency fuel shut-off shall stop engine within 10 s
from the time the manual shut-off handle is actuated.
3.3.5.4 In-tank fuel pump. The pump shall be capable of producing a minimum pressure
of 5 pounds per square inch (psi) at the engine end of the fuel lines disconnect, under no-flow
conditions.
3.3.5.5 Fuel transfer system. The fuel transfer system shall be capable of transferring fuel
from the vehicle fuel tanks to a remote receptacle at a rate of not less than 25 gal/min. Also, the
system shall be capable of transferring fuel from a remote supply to the vehicle fuel tanks at a rate
of not less than 15 gal/min.
3.3.5.6 Heater, fuel feed. The vehicle fuel system shall produce a minimum pressure of
7 psi at the outlet of the heater pump line.
3.3.5.7 Throttle linkage. With the throttle pedal depressed to within 0.19 in. of the pedal
stop, the throttle shall be at full throttle position.
3.3.6 Hydraulic reservoir and lines. Hydraulic reservoir and line shall function without
leaking.