MIL-DTL-62013E(AT)
3.3.2.4 Cargo area personnel heater kit (primary) (M548A1). When installed, the
(primary) cargo area personnel heater kit shall provide heat for personnel in the rear cargo area in
ambient temperatures down to -25°F (see 4.5.6.4).
3.3.2.5 Cargo area personnel heater kit (secondary) (M548A1). When installed, the
(secondary) cargo area personnel heater kit shall supplement the (primary) cargo area personnel
heater kit during operations in ambient temperatures from -25°F to -65°F. The insulated cargo
cover shall provide protection for personnel and material in the cargo area in ambient air
temperatures down to -65°F. The insulated cargo cover shall be water, dust and snow proof
(see 4.5.6.5).
3.3.2.6 Engine coolant heater kit (M548A1). When installed, the engine coolant heater
kit shall assure engine starting and operation in ambient air temperatures from -25°F to -65°F.
The engine coolant heater shall be capable of operating for a minimum of twelve hours on battery
power alone without discharging the battery to a level that would prevent satisfactory starting of
the engine (see 4.5.6.6).
3.3.2.7 Air brake kit (M548A1). When installed, the air brake kit shall adequately
function with air brakes on applicable vehicles or equipment. NOTE: The air brake kit is
required on carriers that are to be used as prime movers of vehicles or of equipment that has air
brakes (see 4.5.6.7).
3.3.2.8 Material handling kit (M548A1). When installed, the material handling kit shall be
capable of loading material weighing up to 1500 pounds (lb) into the cargo area. This kit shall be
capable of being mounted either left of center, right of center, or in a center location of the cargo
area, without interference (see 4.5.6.8).
3.3.2.9 Machine gun kit (M548A1). When mounted on vehicle, the machine gun kit shall
be capable of supporting the machine gun when firing, and allow the gun to rotate 360° to the
right and left without interference or binding (see 4.5.6.9).
3.3.3 Doors, windows, covers, and miscellaneous chassis items. All doors, windows,
covers, hatches, vision devices, receptacles, ducts, vents, panels, stowage boxes, seats, locking
devices and fenders shall conform to applicable drawings. When installed, they shall fit and
function without interference. When shut, all doors, windows, hatches, and covers shall be water,
dust, and snow resistant (see 4.5.2 and 4.5.7).
3.3.4 Engine. The engine shall conform to MIL-PRF-62140 and shall operate throughout
all speed ranges without evidence of cooling system, lubricant, or fuel leakage (see 4.5.2
and 4.5.8).